Sikafloor®-122 Level Universal
MULTI-PURPOSE SELF LEVELLING COMPOUND
Sikafloor®-122 Level Universal self levelling compound is a 1-part, ready to use, cement based floor leveller. Suitable for smoothing and levelling internal uneven rigid floors, prior to applying final wearing coverings such as carpets, sheet vinyl, lino, tiles, laminates and timber.
- Self smoothing and highly fluid.
- Low shrinkage.
- Easy to apply by pump or manual application.
- 2-4 hours walk on time (+20 °C).
- Can be overlaid in approx. 8 hours (+20 °C).
- Maintains good workability and joint healing.
- Good surface appearance and hardness.
- Protein and formaldehyde free.
Usage
Levelling/smoothing- Concrete.
- Sand/cement screeds (not anhydrite).
- Quarry tiles, terrazzo, ceramic tiles.
- Underfloor heating applications beneath heating cables/pipes.
Advantages
- Self smoothing and highly fluid.
- Low shrinkage.
- Easy to apply by pump or manual application.
- 2-4 hours walk on time (+20 °C).
- Can be overlaid in approx. 8 hours (+20 °C).
- Maintains good workability and joint healing.
- Good surface appearance and hardness.
- Protein and formaldehyde free.
Packaging
20 kg Bag
Colour
Grey Powder
Product Details
APPROVALS / STANDARDS
Meets the requirements of EN 13813 class CT-C20-F5.
Chemical Base
Cement and aggregate based
Shelf Life
9 months from date of manufacture if stored correctly.
Storage Conditions
Store properly in original, unopened and undamaged sealed packaging in
dry conditions at temperatures between +5 °C and +35 °C.
Density
2.02 kg/l ± 0.03 (fresh mortar)
Compressive Strength
> 20 N/mm² (after 28 days / +20 °C) (EN 13892-2)
Flexural Strength
> 5 N/mm² (after 28 days / +20 °C) (EN 13892-2)
Thermal Compatibility
Suitable for use with underfloor heating systems (not for embedment).
Reaction to Fire
A1fl
Application
Layer Thickness
Featheredge to 6 mm
Relative Air Humidity
< 75 % max
Substrate Temperature
+5 °C min. / +35 °C max.
Pot Life
20 minutes in conditions of +23 °C / 50 % r.h
The temperature will affect the pot life. Application at temperatures above
+23 °C will reduce the pot life and the working time. Temperatures below
+23 °C will increase the pot life and extend the working time.
Waiting Time / Overcoating
At +20 °C and 50 % relative humidity:
Foot traffic 2-4 hours
Cover ~8 hours
Times are approximate and at +23 °C and 50 % r.h. and will be affected by changing substrate and ambient conditions, particularly the temperature and relative humidity. When overcoating Sikafloor®-122 Level Universal always ensure the moisture content has achieved the required value for the coating product, as the waiting time will vary with the application thickness and ambient humidity (refer to the top coat product data sheet).
Applied Product Ready for Use
Lightly serviceable ~ 24 hours
Fully serviceable ~ 7 days
Note: Times are approximate and will be affected by changing substrate and ambient conditions, particularly the temperature and relative humidity.
Consumption
20 kg will cover approx. 4 m² at 3 mm thickness. This figure may vary due to surface area, porosity, surface profile, variations in level or wastage etc.
SUBSTRATE QUALITY
The concrete/screed should be at least 28 days old. The surface must be dry, clean, structurally sound and posses an effective dampproof membrane. The surface should be free from residual adhesives, oil, grease, wax, loose flaky paint, dust, laitance, etc. that could reduce adhesion. Beware of condensation; the substrate and uncured screed must be at least 3 °C above dew point to reduce the risk of condensation, blooming or cement laitance on the floor finish. Switch off underfloor heating 24 hours before, and for 24 hours after, application. Ensure floor temperature is > +5 °C. If in doubt, apply a test area first.
SUBSTRATE PREPARATION
Weak concrete must be removed and surface defects such as blowholes and voids must be fully exposed. Repairs to the substrate must be carried out using appropriate products such as Sika® concrete repair mortars.
PRIMING
Normal Absorbent Concrete/Screed:
These substrates do not normally require priming. If the substrate is strong and has a sufficiently rough texture, damp down floor with clean water without leaving puddles and allow to surface dry. If water is absorbed immediately into substrate, treat as porous surface.
Porous/Concrete Screed:
All dust, loose and friable material must be completely removed from all surfaces before application of the product, preferably by brush and/or vacuum. Seal the surface with SikaBond® PVA+ (1 part PVA to 4 parts clean water) ensuring the surface is well coated, then allow to dry. For highly porous substrates it may be necessary to apply more than one coat of primer to prevent pinholes and cracking/debonding of Sikafloor®-122 Level Universal.
Non-Porous/Dense Substrates: (quarry/ceramic tiles, terrazzo and smooth concrete etc):
Mechanically roughen surfaces by grinding or scarifying to provide a mechanical key - specialist advice and machinery may be required. Alternatively, apply a bonding coat of undiluted SikaBond® PVA+ and allow to become tacky before applying the levelling compound.
MIXING
Sikafloor®-122 Level Universal will require 3.4 - 3.5 litres of clean water. Always add the powder to the water. Mix in a suitable clean container using a mechanical mixer with a spiral mixing paddle at slow speed until fully mixed and a smooth consistency achieved. Occasionally during hot weather the product may require remixing during the 15 - 20 minute pot life to reactivate the self-levelling characteristics. Do NOT add extra water. Discard any unused material after 20 minutes from initial mixing. If the product starts to stiffen or set DO NOT try to remix or add extra water.
Mixing Time
Mix thoroughly for a minimum of 3 minutes.
Mixing Tools
Use an electric stirrer (< 500 rpm).
APPLICATION
Sikafloor®-122 Level Universal can be applied from a maximum thickness of 6 mm down to a featheredge. Pour the mixed product onto the floor and spread evenly with a steel trowel to form a thin, tight scrape coat within working time. Immediately add further quantities of mixed product to leave a smooth finish (if not, trowel again when the surface is still damp but firm to the touch). If required use a spiked roller, within working time, to provide a more uniform surface appearance. Additional layers, each not exceeding 6 mm, may be applied to achieve the required depth. Prime with Sika Bond PVA+ diluted 1:3 with water between layers.
CURING TREATMENT
In warm weather, mist spraying onto the surface should be used to compensate for moisture loss and to eliminate drying or shrinkage cracking.
Eliminate any through draughts which can cause moisture loss.
CLEANING OF TOOLS
All tools and equipment should be cleaned immediately with water before the levelling compound hardens.