Sikafloor® MultiFlex PS-36 ESD
Sikafloor® MultiFlex PS-36 ESD is a coloured, conductive, low-VOC, crack-bridging polyurethane flooring system. It provides a hard-wearing, seamless, tough-elastic, low-maintenance finish which is resistant to many chemicals.
- Low VOC emissions
- Easy to apply
- Easy to refurbish, topcoat can be recoated
- Good resistance to UV exposure
- Good yellowing resistance
- Conforms to the requirements of ANSI/ESD S20.20 and IEC 61340-5-1
System Structure
1
Primer (Alternative)
2
Body Coat (Sikafloor® BC 375 N)
3
Final ESD Roller-Coat
Usage
The System is used in industrial buildings such as:- Electronic facilities and data centres
- Clean rooms
- Microbiology and microchemistry production areas
- Automotive facilities
- The System may only be used for interior applications.
Advantages
- Low VOC emissions
- Easy to apply
- Easy to refurbish, topcoat can be recoated
- Good resistance to UV exposure
- Good yellowing resistance
- Conforms to the requirements of ANSI/ESD S20.20 and IEC 61340-5-1
Colour
Available in various colour shades.
Appearance
Smooth matt finish
System Details
APPROVALS / STANDARDS
Fire classification report EN 13501-1, GHENT, No. CR 24-0148-01
System Structure
Layer | Product |
1. Primer | Sikafloor®-150, or Sikafloor®-151, or Sikafloor®-1590 |
2. Base coat + Earthing connection | Sikafloor® BC 375 N + Sikafloor® Conductive Set |
3. ESD Topcoat | Sikafloor®-305 W ESD |
System structure: The system structure described in the table must not be changed. Contact Sika Technical Service for information on choosing the right primer for your project
Composition
Polyurethane
Nominal thickness
~1.5–2.0 mm
Tensile adhesion strength
≥ 1.5 MPa | (EN 1542) |
Reaction to Fire
Class Bfl-s1 | (EN 13501-1) |
Electrostatic Behaviour
Resistance to ground | RG < 109 Ω | (IEC 61340-4-1) |
Typical average resistance to ground | RG < ~ 105–106 Ω | (EN 1081) |
Body voltage generation | < 100 V | (IEC 61340-4-5) |
System Resistance (Person/Floor/Shoe) | RG < 109 Ω | (IEC 61340-4-5) |
ESD MEASUREMENT CONDITIONS AND SPECIFICATIONS
All measurement values for the system stated in the System Data Sheet (except those referring to proof statements) were measured using the following equipment and ambient conditions:
Condition or Equipment | Specification |
Size of ESD-footwear | 42 (EU) (UK: 8; US: 8.5) |
Test person weight | 90 kg |
Ambient conditions | +23 °C and 50 % relative humidity |
Measuring device for measuring resistance to ground | Metriso 2000 or 3000 (Warmbier) or comparable |
Surface resistance probe | Carbon Rubber electrode. Weight: 2.50 kg |
Rubber pad hardness | Shore A (60 ±10) |
Measuring device for measuring body voltage generation | Walking Test Kit WT 5000 (Warmbier) or comparable |
ESD footwear requirements
The ESD shoes used in the EPA must have a resistance of < 5 MOhm according to IEC 61340-4-3 at climate class 1 (12 % relative humidity and +23 °C). In order to achieve charges of < 30 volts of human body charge during the walking test (at 12 % relative humidity and +23 °C), we recommend using the following ESD shoes: Weeger ESD clog, art. 48512-30, www.schuh-weeger.de.
Note: Measurement results can be affected by ESD clothing, ambient conditions, measurement equipment, cleanliness of the floor and the test personnel.
Application
Ambient Air Temperature
Maximum | +30 °C |
Minimum | +10 °C |
Relative Air Humidity
Maximum | 75 % r.h. |
Dew Point
Refer to the individual Product Data Sheet.
Substrate Temperature
Maximum | +30 °C |
Minimum | +10 °C |
Substrate Moisture Content
Refer to the individual Product Data Sheet.
Waiting Time / Overcoating
When using Sikafloor®-1590 refer to the individual Product Data Sheet for specific information on waiting time to overcoating.
Before applying Sikafloor® BC 375 N on the primer layer allow:
Temperature | Minimum | Maximum |
+10 °C | ~17 hours | ~4 days |
+20 °C | ~9 hours | ~48 hours |
+30 °C | ~7 hours | ~24 hours |
Before applying Sikafloor®-305 W ESD on Sikafloor® BC 375 N allow:
Temperature | Minimum | Maximum |
+10 °C | ~30 hours | ~7 days |
+20 °C | ~24 hours | ~5 days |
+30 °C | ~16 hours | ~3 days |
Before applying Sikafloor®-305 W ESD on Sikafloor®-305 W ESD allow:
Temperature | Minimum | Maximum |
+10 °C | ~48 hours | ~10 days |
+20 °C | ~24 hours | ~8 days |
+30 °C | ~16 hours | ~7 days |
Note: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity.
Applied Product Ready for Use
Temperature | Foot traffic | Light traffic | Full cure |
+10 °C | ~48 hours | ~5 days | ~10 days |
+20 °C | ~24 hours | ~3 days | ~8 days |
+30 °C | ~16 hours | ~2 days | ~7 days |
Note: Times apply when the last layer of the system has been applied. Times are affected by changing ambient conditions, particularly temperature and relative humidity.
Consumption
Layer | Product | Consumption |
Primer | Sikafloor®-150 Plus, or Sikafloor®-151, or Sikafloor®-1590 | 1-2 × 0.3–0.5 kg/m² |
Levelling | Sikafloor®-150 Plus, or Sikafloor®-151, or Sikafloor®-1590 | Refer to the individual Product Data Sheet. |
Base coat | Sikafloor® BC 375 N | 2.0 kg/m² |
Earthing connection | Sikafloor® Conductive Set | 1 Earthing point per approx. 200–300 m², min. 2 per room |
ESD Topcoat | Sikafloor®-305 W ESD | 1 - 2 × 0.18-0.2 kg/m²/layer diluted with 10% of water |
Note: Consumption data is theoretical and does not allow for any additional material due to surface porosity, surface profile, variations in level, wastage or any other variations. Apply the product to a test area to calculate the exact consumption for the specific substrate conditions and proposed application equipment.
APPLICATION
ESD CONDUCTIVITY MEASUREMENTS
The recommended number of conductivity measurements is specified in the following table:
Application Area | Number of measurements |
< 10 m² | 6 |
≥ 10 m² and < 100 m² | 10 to 20 |
≥ 100 m² and < 1000 m² | 50 |
≥ 1000 m² and < 5000 m² | 100 |
If the measurements yield values that are outside of the agreed specification, follow these steps:
1. Carry out one additional measurement within a radius of approximately 30 cm around the original measuring point.
If the value of the new measurement meets the agreed specification, the original measurement can be disregarded.If the value of the new measurement does not meet the agreed specification, repeat the measurement described above until the fulfilment of the requirements have been verified. If the requirements cannot be verified, contact Sika Technical Services.
INSTALLATION OF EARTHING POINTS
Refer to Sika Method Statement: Sika Method Statement — Sikafloor® mixing and Application.
Number of earthing connections per room: Minimum of 2 earthing connections. The optimum number of earthing connections depends on the local conditions and must be specified on drawings or other contract documentation.