Sikafloor®-100 Level is a polymer-modified cementitious floor levelling compound with very low VOC emissions. It provides a smooth finish compound on subfloors at a layer thickness of 2–10 mm before the application of resilient flooring or ceramic tiles.
- Layer thickness of 2–10 mm
- Self-levelling
- Smooth finish
- Suitable for use with underfloor heating systems
- Pumpable
- Suitable for castor wheels in accordance with EN 12529
- Causes very little tension or stress on the substrate
- Waterproof against dispersion adhesives
Usage
Sikafloor®-100 Level is used for:- Smoothing and levelling interior residential and non-industrial subfloors before applying a covering
- Ceramic tiles
- Resilient floor coverings such as linoleum and vinyl
- Textile floor coverings such as carpet
- The Product may only be used by experienced professionals.
Advantages
- Layer thickness of 2–10 mm
- Self-levelling
- Smooth finish
- Suitable for use with underfloor heating systems
- Pumpable
- Suitable for castor wheels in accordance with EN 12529
- Causes very little tension or stress on the substrate
- Waterproof against dispersion adhesives
Packaging
25 kg
Refer to the current price list for available packaging variations.
Colour
Grey powder
Product Details
ENVIRONMENTAL INFORMATION
Contributes towards satisfying Materials and Resources (MR) Credit: Building Product Disclosure and Optimization — Material Ingredients under LEED® v4
VOC emission classification GEV Emicode EC1plus
APPROVALS / STANDARDS
-
CE marking and declaration of performance based on EN 13813:2002 Screed material and floor screeds — Screed material — Properties and requirements — Cementitious screed material
Chemical Base
Cement-based, polymer-modified
Shelf Life
6 months from date of production
Storage Conditions
The Product must be stored in original, unopened and undamaged packaging in dry conditions at temperatures between +5 °C and +35 °C. Always refer to the packaging. Refer to the current Safety Data Sheet for information on safe handling and storage.
Product Declaration
EN 13813:2002 | Class CT-C25-F6 |
Compressive Strength
Cured 28 days at +23 °C | ≥ 25 N/mm2 |
Flexural Strength
Cured 28 days at +23 °C | ≥ 6 N/mm2 |
Reaction to Fire
A1fl | (EN 13501-1) |
Application
Mixing Ratio
Pourable consistency | 5.8–6.0 L |
Layer Thickness
Maximum | 10.0 mm |
Minimum | 2.0 mm |
Product Temperature
Maximum | +25 °C |
Minimum | +10 °C |
Ambient Air Temperature
Maximum | +30 °C |
Minimum | +10 °C |
Relative Air Humidity
< 75 %
Substrate Temperature
Maximum | +25 °C |
Minimum | +10 °C |
Pot Life
At +20 °C | 30 minutes |
Waiting Time / Overcoating
Before applying a floor covering, make sure the Product has achieved the moisture content value required by the covering manufacturer. Refer to the manufacturer's Product Data Sheet for the respective covering.
The Product can be covered as follows:
Floor covering | Layer thickness | Typical waiting time |
Resilient coverings | ≤ 3 mm | 24 hours |
Resilient coverings | ≤ 5 mm | 48 hours |
Resilient coverings | ≤ 10 mm | 72 hours |
Ceramic tiles with the Product applied on a concrete or cementitious screed substrate | ≤ 2–10 mm | 4–6 hours |
Ceramic tiles with the Product applied on other substrates | ≤ 2–10 mm | 24 hours |
Times measured at an ambient temperature of +20 °C, a substrate temperature of +15 °C with a 65 % relative humidity.
Note: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity. Times are also dependant on layer thickness.
Applied Product Ready for Use
Foot traffic: 3 hours
Note: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity.
Consumption
1.5 kg/m2 per mm of thickness
Note: Consumption data is theoretical and does not allow for any additional material due to surface porosity, surface profile, variations in level, wastage or any other variations. Apply the Product to a test area to calculate the exact consumption for the specific substrate conditions and proposed application equipment.
EQUIPMENT
Select the most appropriate equipment for the project.
SUBSTRATE PREPARATION EQUIPMENT
Abrasive blast cleaning equipment
Grinding equipment
Planing machine
Scarifying machine
Abrading (sanding) equipment
Industrial vacuuming equipment
For other types of preparation equipment, contact Sika Technical Services.
MIXING EQUIPMENT
Electric single-paddle or double-paddle mixer (< 600 rpm) with helical, disc-shaped mixing paddle
Scraper
Clean mixing containers
For other types of mixing equipment, contact Sika Technical Services.
APPLICATION EQUIPMENT
Mixed material carrier
Pin leveller (pin rake)
Surface blade
Screed rake
Notched trowel
Smoothing trowels
Spiked roller
For types of pumping equipment, contact Sika Technical Services.
SUBSTRATE QUALITY
Suitable substrates:
Concrete
Cementitious screeds
Rapid cement screeds
Calcium sulphate screeds
Substrate quality:
Cementitious substrates such as concrete and screed must be sound.
Substrates must be clean, dry and free of all contaminants such as dirt, oil, grease, polish, coatings, water-soluble and water-resistant adhesives, varnish, laitance, surface treatments and loose friable material.
SUBSTRATE PREPARATION
IMPORTANT: Impaired Product properties due to substrates with rising moisture
- Do not apply the Product on substrates with rising moisture.
- If rising moisture can occur, apply an effective damp-proof membrane that complies with the applicable national standard.
IMPORTANT: Surface defects due to voids in the substrate
Voids and blow holes in the substrate will weaken the surface and damage the covering Product if not repaired during the preparation process.
- Fully expose blow holes and voids during surface preparation to identify the required repairs.
- Remove separation and sinter layers.
- IMPORTANT: The final texture of the substrate must be open-textured and gripping. Remove weak cementitious and levelling layers, and fully expose defects such as blow holes and voids. Note: Suitable methods for surface preparation are abrasive blast cleaning, grinding, planing or scarifying equipment, depending on the type of substrate.
- Before applying the Product, remove all dust, loose and friable material from the application surface with industrial vacuuming equipment.
- Repair and fill blow holes and voids using appropriate products from the Sikafloor®, Sikadur® and Sikagard® range of materials.
- Any repair materials must be cured before starting to apply the Product.
NORMALLY-ABSORBENT SUBSTRATES SUCH AS CONCRETE, CEMENT SCREEDS AND RAPID CEMENT SCREEDS
- Prime the substrate with Sikafloor®-01 Primer diluted 1:3 with water.
CALCIUM SULPHATE SUBSTRATES WITH PRODUCT LAYER THICKNESS OF LESS THAN 10 MM
- Prime the substrate with Sikafloor®-01 Primer diluted 1:1 with water.
CALCIUM SULPHATE SUBSTRATES WITH PRODUCT LAYER THICKNESS OF MORE THAN 10 MM
- Prime the substrate twice with Sikafloor®-151.
- Fully broadcast the primer with quartz sand (0.3–0.8 mm).
- If the primer is not fully broadcast, apply Sikafloor®-02 Primer before applying the Product.
NON-ABSORBENT SUBSTRATES SUCH AS CERAMIC TILES, WATER-RESISTANT ADHESIVE RESIDUES, EPOXY RESIN LAYERS
- Prime the substrate with Sikafloor®-02 Primer undiluted or Sikafloor®-01 Primer undiluted.
SUBSTRATES WITH WATER-SOLUBLE ADHESIVE RESIDUE
- Prime the substrate with Sika® Primer MB Rapid, or Sikafloor®-150 Plus, Sikafloor®-151.
- Fully broadcast the primer with kiln-dried quartz sand.
- If the primer is not fully broadcast, apply Sikafloor®-02 Primer before applying the Product.
MIXING
IMPORTANT: Incompatibility with Portland cement
The Product is a special cement binder-based mortar which can expand in contact with standard Portland cements.
- Do not mix or blend the Product with Portland cements or other binders.
IMPORTANT: Reduced Product performance due to overaddition of water
- Do not add more than the prescribed water amount to the Product.
- Pour the minimum amount of water into a suitable clean mixing container.
- Use an electric single-paddle or double-paddle mixer (< 600 rpm) with a helical, disc-shaped mixing paddle. Mix the water slowly while gradually adding the complete bag of the Product.
- Mix continuously for 2 minutes to achieve a smooth, uniform mix. If necessary, add more water to achieve the required consistency.
- Allow to stand for 2 minutes to allow entrained air to escape and for the mixture to mature.
- Mix for a further 1 minute.
APPLICATION
IMPORTANT: Strictly follow installation procedures
Strictly follow installation procedures as defined in Method Statements, application manuals and working instructions which must always be adjusted to the actual site conditions.
IMPORTANT: Subfloor cracking due to incorrect assessment of site requirements
- Bring edge and movement joints through to the finished surface and protect them so the Product will not flow into the joint.
- Use an isolating strip to prevent the Product bonding onto vertical surfaces, such as pipes, ducts, conduits, walls and columns.
- Protect the freshly-applied Product from high ambient temperatures, direct sunlight and draughts.
Subfloor thickness and flatness
Note: The Product must be applied to the required thickness and surface flatness as specified by the floor covering manufacturer.
APPLYING A SINGLE LAYER
- Pour the mixed Product onto the substrate.
- Spread the Product evenly using a smoothing trowel, surface blade, screed rake or pin leveller (pin rake) to the required thickness.
- Allow the Product to smooth over the substrate.
- Immediately use a spiked roller to remove any trowel marks or surface defects, as required. Note: This step is more likely if a trowel was used for spreading, rather than a pin leveller.
APPLYING TWO LAYERS
- Pour the mixed Product onto the substrate.
- Spread the Product evenly using a smoothing trowel, surface blade, screed rake or pin leveller (pin rake) to the required thickness.
- Allow the Product to smooth over the substrate.
- Immediately use a spiked roller to remove any trowel marks or surface defects, as required. Note: This step is more likely if a trowel was used for spreading, rather than a pin leveller.
- Allow the first layer to harden.
- Prime the first layer with Sikafloor®-01 Primer diluted 1:1 with water.
- In a two-layer application, the thickness of the second layer must not exceed the thickness of the first layer. Apply a second layer of the Product.
CLEANING OF TOOLS