Sikadur®-33
High-performance epoxy adhesive for structural bonding
Sikadur®-33 is a thixotropic 2-part epoxy structural adhesive supplied in a cartridge.
- Good adhesion to damp concrete surfaces.
- Very good adhesion to many construction materials.
- Thixotropic: non-sag in vertical and overhead applications.
- Very good load capacity.
- Hardens without shrinkage.
- Styrene-free.
- EPD available.
Usage
The Product is used as a structural adhesive for:- Concrete.
- Hard natural stone.
- Ceramics.
- Fibre cement.
- Mortar.
- Brick masonry.
- Hollow and solid masonry.
- Steel.
- Iron.
- Wood.
- Corners and edges.
- Hole and void filling.
- Joint arrises.
- Static crack filling and sealing.
- Handrails, balustrades and supports.
- Window frames, door frames, and windowsills.
Advantages
- Good adhesion to damp concrete surfaces.
- Very good adhesion to many construction materials.
- Thixotropic: non-sag in vertical and overhead applications.
- Very good load capacity.
- Hardens without shrinkage.
- Styrene-free.
- EPD available.
Packaging
250 ml cartridge | Box of 12 × 250 ml |
400 ml side-by-side cartridge | Box of 12 × 400 ml |
Refer to the current price list for available packaging variations.
Colour
Part A | White |
Part B | Grey |
Part A+B mixed | Grey |
Product Details
ENVIRONMENTAL INFORMATION
-
Environmental Product Declaration (EPD) in accordance with EN 15804. EPD independently verified by Institut für Bauen und Umwelt e.V. (IBU).
-
Contributes towards satisfying Materials and Resources (MR) Credit: Building product disclosure and optimization — Environmental Product Declarations under LEED® v4.
-
Contributes towards satisfying Materials and Resources (MR) Credit: Building Product Disclosure and Optimization — Material Ingredients under LEED® v4.
APPROVALS / STANDARDS
-
CE marking and declaration of performance based on EN 1504-4:2004 Products and systems for the protection and repair of concrete structures — Structural bonding.
Chemical Base
Epoxy resin
Shelf Life
12 months from date of production
Storage Conditions
The Product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +10 °C and +30 °C. Always refer to packaging.
Refer to the current Safety Data Sheet for information on safe handling and storage.
Density
Mixed resin at +23 °C | 1.35 kg/l |
Compressive Strength
Cured 14 days at +23 °C | 50 N/mm2 |
Flexural Strength
Cured 14 days at +23 °C | 20 N/mm2 |
Tensile Strength
Cured 14 days at +23 °C | 13 N/mm2 |
Tensile adhesion strength
Curing Time | Substrate | Adhesion strength |
3 days | Concrete dry | > 5 N/mm2 (100 % concrete failure) |
3 days | Concrete moist | > 5 N/mm2 (100 % concrete failure) |
3 days | Steel sandblasted | > 10 N/mm2 |
3 days | Brick dry | > 1.5 N/mm2 (100 % brick failure) |
Shrinkage
Hardens without shrinkage
Coefficient of Thermal Expansion
9.3 × 10-5 1/K Linear expansion between +23 °C and +60 °C | (EN 1770) |
Glass transition temperature
Cured 7 days at +23 °C | +49 °C |
Application
Mixing Ratio
Part A : Part B | 1 : 1 by volume |
Layer Thickness
Maximum | 10 mm |
Minimum | 0.5 mm |
Sag Flow
Non-sag, suitable for overhead application
Product Temperature
Maximum | +35 °C |
Minimum | +10 °C |
Ambient Air Temperature
Maximum | +35 °C |
Minimum | +10 °C |
Relative Air Humidity
Maximum at +25 °C | 85 % |
Dew Point
Beware of condensation. Substrate temperature during application must be at least +3 °C above dew point.
Substrate Temperature
Maximum | +35 °C |
Minimum | +10 °C |
Substrate Moisture Content
Substrates must be dry or matt damp (no standing water).
Pot Life
Tested at +23 °C | 60 minutes |
Open Time
Temperature | Open Time |
+10 °C | 210 minutes |
+20 °C | 90 minutes |
+35 °C | 45 minutes |
Minimum cartridge temperature +10 °C
Curing Time
Temperature | Curing Time |
+10 °C | 3 days (80 % of performance) |
+20 °C | 2 days (80 % of performance) |
+35 °C | 1 day (80 % of performance) |
Minimum cartridge temperature +10 °C
EQUIPMENT
250ml cartridges require a standard, keyed action applicator gun.
400ml cartridges require a 1:1 ratio, side by side applicator gun, with a thrust ratio of 26:1 (available from Sika).
SUBSTRATE QUALITY
CONCRETE, MASONRY, MORTAR, STONE
Concrete and mortar must be at least 28 days old.
Substrates must be sound, clean, dry or matt damp but free of standing water. Substrates must be free of contaminants such as ice, dirt, oil, grease, coatings, laitance, efflorescence, surface treatments and loose friable material.
STEEL
Surfaces must be sound, clean, dry and free of contaminants such as dirt, oil, grease, coatings and loose friable material.
WOOD
Surfaces must be sound, clean, dry and free of contaminants such as dirt, oil, grease, coatings and loose friable material.
SUBSTRATE PREPARATION
IMPORTANT
Reduced adhesion due to surface contamination
Surface contaminants such as dust and loose material, including the contaminants generated during substrate preparation, can reduce the Product's performance.
Before applying the Product, clean thoroughly all substrate surfaces using vacuum or dust removal equipment.
CONCRETE, MASONRY, MORTAR OR STONE
Suitable techniques for substrate preparation include the following:
-
Abrasive blast cleaning.
-
Needle gunning.
-
Light scabbling.
-
Bush hammering.
-
Grinding.
Prepare the substrate mechanically using a suitable technique.
The substrate has an open-textured, gripping surface profile.
STEEL
Suitable techniques for substrate preparation include the following:
-
Abrasive blast cleaning.
-
Rotating wire brush.
-
Grinding.
Prepare the substrate mechanically using a suitable technique.
The substrate has a bright metal finish with a surface profile to satisfy the necessary tensile adhesion strength requirement.
WOOD
Prepare the substrate by planing, sanding or using other suitable equipment.
MIXING
PREPARING THE CARTRIDGE
- Unscrew and remove the cap from the cartridge.
-
Remove the plug from the end of the cartridge.
Note: 250 ml cartridge only. - Screw the static mixer nozzle to the open cartridge.
- Place the cartridge into the application gun.
APPLICATION
IMPORTANT
Damage due to unsupported heavy components applied vertically or overhead
Full adhesion is not achieved before the Product has fully hardened. Hardening depends on ambient temperatures. Unsupported heavy components might fall down when not supported.
Provide temporary support for heavy components until the Product has fully hardened.
Hardened material in the static mixer nozzle
Note: When work is interrupted, the static mixer nozzle can remain on the cartridge after the pressure of the sealant dispenser has been released.
Attach a new nozzle if the resin has hardened in the nozzle when work is resumed.
BONDING
Preconditions
Prior to application confirm dew point conditions before and during application.
- Pump the Product until both parts are extruded as one consistent colour.
- Release the gun pressure and clean the static mixer opening with a cloth.
- Discard inconsistently coloured Product parts.
- Apply the Product to the prepared substrate using specific application gun.
- For optimum adhesion apply the adhesive to both surfaces that require bonding.
- For heavy components positioned vertically or overhead, provide temporary support until the Product has fully hardened.
- Immediately clean tools with Sika® Thinner C.
- Wash hands and skin thoroughly with warm soap water.
REPAIR
Preconditions
Prior to application confirm dew point conditions before and during application.
- Pump the Product until both parts are extruded as one consistent colour.
- Release the gun pressure and clean the static mixer opening with a cloth.
- Discard inconsistently coloured Product parts.
- Apply the Product to the prepared substrate using specific application gun.
- Finish the surface of the repair with a spatula or trowel if required.
- Immediately clean tools with Sika® Thinner C.
- Wash hands and skin thoroughly with warm soap water.
JOINT FILLING AND CRACK SEALING
Preconditions
Prior to application confirm dew point conditions before and during application.
- Pump the Product until both parts are extruded as one consistent colour.
- Release the gun pressure and clean the static mixer opening with a cloth.
- Discard inconsistently coloured Product parts.
- Apply the Product to the prepared substrate using specific application gun.
- For a smooth finish tool the surface of the joint or crack using a spatula.
- Immediately clean tools with Sika® Thinner C.
- Wash hands and skin thoroughly with warm soap water.
CLEANING OF TOOLS
Clean all tools and application equipment with Sika® Thinner C immediately after use. Hardened material can only be removed mechanically.