Sikafloor®-221 W Conductive
Epoxy Water-based Electrostatic Conductive Flooring Primer
Sikafloor®-221 W Conductive is a 2-part, epoxy, water-based, electrostatic conductive flooring primer with increased electrical resistance. It is part of the selected Sikafloor® ECF and ECD flooring systems.
- Water-based
- Easy to apply
- High electrostatic conductivity
- Applied by roller
Usage
- As a conductive primer below Sikafloor® electrostatic conductive floor coatings.
- Flooring that needs to comply with the requirements of the standard VDE 100-600.
Advantages
- Water-based
- Easy to apply
- High electrostatic conductivity
- Applied by roller
Packaging
Part A | 4,98 kg container |
Part B | 1,02 kg container |
Part A + B | 6 kg unipacks |
Refer to current price list for packaging variations.
Colour
Part A - resin | black, liquid |
Part B - hardener | white, liquid |
Final colour: black
Product Details
ENVIRONMENTAL INFORMATION
Conformity with LEED v4 MR credit 4 option 2: Building product disclosure and optimization - Material ingredients.
APPROVALS / STANDARDS
- CE Marking and Declaration of Performance to EN 1504-2 - Surface protection product for concrete - Coating.
- CE Marking and Declaration of Performance to EN 13813 - Resin screed material for internal use in buildings.
- Insulation Resistance DIN VDE 0100-600, Sikafloor® MultiDur ES-47 ECF, kiwa, Test report No. P 12174-4-E.
- Insulation Resistance DIN VDE 0100-600, Sikafloor® MultiDur ES-47 ESD, kiwa, Test report No. P 12174-2-E.
- Insulation Resistance DIN VDE 0100-600, Sikafloor® MultiDur ES-48 ECF, kiwa, Test report No. P 12174-3-E.
- Insulation Resistance DIN VDE 0100-600, Sikafloor® MultiDur ES-49 ECF, kiwa, Test report No. P 12174-5-E.
- Insulation Resistance DIN VDE 0100-600, Sikafloor® MultiDur ES-52 ESD, kiwa, Test report No. P 12174-1-E.
- Test of floor IEC 61340-4-1, Sikafloor® MultiDur ES-52 ESD, RISE, Test report No. 9P07719 C.
- IEC 61340-5-1, Sikafloor® MultiDur ES-52 ESD, RISE, Approval No. 230-19-0040.
Chemical Base
Water-based epoxy
Shelf Life
12 months from date of production.
Storage Conditions
The product must be stored in original, unopened and undamaged packaging in dry conditions at temperatures between +5 °C and +30 °C. Always refer to packaging.
Density
Part A | 1,15 kg/l |
Part B | 1,09 kg/l |
Mixed Resin | 1,14 kg/l |
Values at +23 °C.
Solid content by mass
~40 %
Solid content by volume
~32 %
Electrostatic Behaviour
Typical Average Resistance to Ground: | Rg ≤ 104 Ω* |
In Combination with a Sika® Electrostatic Conductive Floor Covering: | Rg ≥ 107 Ω ≤ 109 Ω* |
* Readings may vary, depending on ambient conditions (i.e. temperature, humidity, etc.) and measurement equipment.
Application
Mixing Ratio
Part A : Part B = 83 : 17 (by weight)
Ambient Air Temperature
+10 °C minimum / +30 °C maximum
Relative Air Humidity
75 % maximum
Dew Point
Beware of condensation.
The substrate and uncured applied floor material must be at least +3 °C above dew point to reduce the risk of condensation or blooming on the floor finish.
Substrate Temperature
+10 °C minimum / +30 °C maximum
Substrate Moisture Content
≤ 4 % percentage by weight
The following test methods can be used: Sika®-Tramex Meter, CM-measurement or Oven-dry-method. No rising moisture according to ASTM (Polyethylene-sheet).
Pot Life
Temperatures | Time |
+10 °C | ~120 minutes |
+20 °C | ~90 minutes |
+30 °C | ~30 minutes |
Curing Time
Before overcoating Sikafloor®-221 W Conductive allow:
Substrate Temperature | Minimum | Maximum |
+10 °C | 26 hours | 7 days |
+20 °C | 17 hours | 5 days |
+30 °C | 12 hours | 4 days |
Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
Applied Product Ready for Use
Temperature | Foot Traffic |
+10 °C | ~26 hours |
+20 °C | ~13 hours |
+30 °C | ~8 hours |
Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
Consumption
~0,08–0,10 kg/m²
This figure is theoretical and does not allow for any additional material due to surface porosity, surface profile, variations in level or wastage, etc.
For detailed information, refer to the System Data Sheets.
MIXING
Prior to mixing all parts, mix separately Part A (resin) using an electric single paddle mixer (300–400 rpm) or other similar equipment. Mix liquid and all the coloured pigment until a uniform colour / mix has been achieved. Add Part B (hardener) to Part A and mix Part A + B continuously for at least 2 minutes until a uniformly coloured mix has been achieved. To ensure thorough mixing, pour materials into a clean container and mix again for at least 1 minute to achieve a smooth, consistent, homogeneous mix. Excessive mixing must be avoided to minimise air entrainment. During the final mixing stage, scrape down the sides and bottom of the mixing container with a straight edge trowel or spatula at least once to ensure complete mixing. Mix full units only. Mixing time for A+B = >3 minutes.
APPLICATION
Apply Sikafloor®-221 W Conductive onto the prepared, primed substrate and apply by short pile nylon roller (12 mm), then back roller in two directions at right angles to each other. Ensure a continuous, pore-free coat covers the substrate.
Confirm waiting / overcoating time has been achieved before applying subsequent products.
CLEANING OF TOOLS
Clean all tools and application equipment with water immediately after use. Hardened material can only be removed mechanically.